Connecting Global Safety Technology

ST450 EC H₂S Gas Detector (0-30 ppm, Stainless Steel)

Original manufacturer
Buveco Gasdetection BV, Zuidpool 9, 2801 RW Gouda, The Netherlands
Name
ST450 EC H₂S Gas Detector (0-30 ppm, Stainless Steel)
Model
ST450 EC-H₂S
Part number
5150132-00A

Supply availability and delivery time require confirmation. A catalog reference does not imply stock.

Specifications

Manufacturer approvals / certificationsATEX Directive 2014/34/EU; current validity unknown. Electromagnetic Compatibility Directive 2014/30/EU; current validity unknown. IECEx; current validity unknown.
Ordering Sku5150132-00A
ModelST450 EC-H₂S
Detected GasH₂S
Measuring Range0-30 ppm
Enclosure MaterialStainless Steel
Operating Temperature-20 °C to +50 °C
Relative Humidity5-90% RH (n.c.)
Sensor TypeElectrochemical sensor (2 or 3 electrodes)
DisplayDigital graphic display with backlight
Status LedGreen: OK; Red: Alarm; Yellow: System failure
Power Supply18-30 V DC
Power/current Indication< 2.4 mA = system error; 4-20 mA = normal operation; > 22 mA = overload
Outputs4-20 mA, RS485 Modbus RTU (half-duplex); 2 mA system failure, >20 mA over range
Signal Cable2-wire shielded, 0.75 - 2.5 mm²
Load ImpedanceMax. 300 Ω at 24 V DC
Ingress ProtectionEnclosure: IP66; Sensor: IP6X
Ip Rating NoteIP ratings do not imply that the equipment will detect gas during and after exposure to those conditions.
Enclosure ConstructionAluminium with coating, optional SS
Dimensions179 × 189 × 107 mm (H × W × D)
Enclosure Gas-sensor MaterialSS 316
Weight2.6 kg ± 5% (SS)
Pressure RangeToxic: Atmospheric ± 10%
Certification DirectivesATEX Directive 2014/34/EU; Electromagnetic Compatibility Directive 2014/30/EU
Atex MarkingII 2G Ex db IIC T6 Gb; II 2D Ex tb IIIC T85°C Db
Atex Certificate Number (as Printed)KIWA 16ATEX0008 X
Iecex MarkingEx db IIC T6 Gb; Ex tb IIIC T85°C Db
Iecex Certificate Number (as Printed)IECEx KIWA 16.0003X
Sensor Datasheet NoteMore information can be found in the sensor datasheets.
Hazardous-area NoteFor use in hazardous areas see Consilium ST450 Manual.
Allowed Ex ZonesAllowed in Ex zones 1 and 21
Applicable Ex ZonesEx applications (zone 1/2 and 21/22)
Compatible SystemsCGD50/500, CGS50/500
Mounting OrientationMount the detector in a vertical position, with the sensor pointing downwards.
Sensor-exchange ClearanceLeave at least 11 cm free space below the sensor head for splashguard removal and bump-test hose connection.
Cable-gland WordingAluminium housing: Brass / SS housing SS (thread M20x1.5)
Manufacturer (as Printed)Buveco Gasdetection BV, Zuidpool 9, 2801 RW Gouda, The Netherlands
Publisher/contact (as Printed)Consilium, Salsmästaregatan 21, SE-422 46 Gothenburg, spares.se@consiliumsafety.com
Ip Rating Superscript NoteIP66 plus superscript footnote 1; sensor IP6X; footnote wording retained separately.
Maximum Current Certification NoteMaximum 120 mA according to certification; current validity unknown; historical certification note retained separately.
Pressure Range Conditions (family)Toxic: Atmospheric ± 10%; Oxygen: 80 to 120 kPa
Cable Gland ThreadM20 x 1.5
Cable Gland Material (aluminium Housing)Unknown — source wording does not resolve housing/material pairing: Aluminium housing: Brass / SS housing SS (thread M20x1.5).
Cable Gland Material (ss Housing)Unknown — source wording does not resolve housing/material pairing: Aluminium housing: Brass / SS housing SS (thread M20x1.5).
Replaceable SensorReplaceable electrochemical gas sensor for oxygen and toxic gases.
Display, Status, And BacklightStandard graphic display shows the measured value and local status notifications; backlight supports use in dark areas.
Capacitive-key NavigationCapacitive-key control enables navigation through the user/calibration menu.
Password-secured MenuPassword-secured user menu prevents unauthorized access; user/calibration control requires no additional tools, including magnets.
Zero CalibrationThe user menu provides different features, such as a zero and span calibration.
Span CalibrationThe user menu provides different features, such as a zero and span calibration.
Alarm SetpointsAdjusting alarm set points.
Local Alarm NotificationsLocal alarm indication through notifications on the display and bright colored LED.
Displayed Setpoints And DiagnosticsShowing set points and diagnostic information.
4-20 Ma Output SimulationSimulation of the output signal (4-20 mA) for loop testing.
Self-diagnosticsSelf-diagnostics included
Ex Application Zener-barrier NoteThe gas detector can be used in Ex applications (zone 1/2 and 21/22). without having a zener barrier. This reduces investment costs directly.
Source ApplicationsWastewater plants; Refineries; Confined spaces; Food industry; Marine; Silo storage; Steel industry
SplashguardSplashguard included
Connection DiagramManufacturer page 4 Connections diagram retained as the source figure; terminal, earth, and bonding context is read from that diagram.
Dimensions DiagramManufacturer page 4 Dimensions diagram retained as the source figure.
Drawing DimensionsPage 4 drawing: overall 218 mm; lower segment 92 mm; lower width 127 mm; top width 189 mm; depth 107 mm; hole diameter 7 mm.
Overall Height NormalizationUnknown — source table height 179 mm conflicts with drawing overall height 218 mm; both raw roles are retained.
Optional Accessories5150227-00A — Splash guard, Sensor protection against splash water; 5150228-00A — Inline flow adapter, Inline flow adapter for sample applications, connection 2×6 mm, SS; 5150226-00A — Protective hood, Protective hood SS, for optimal protection in “wet” protection areas, dim. 315×300×138 mm; 5150231-00A — Isolation set EMC/RFI, Isolation board, 160×160 mm; 5150225-00A — Protective bracket, SS bracket, extra protection for use in warehouses
Replacement Sensors5150234-00A — BUSENS D, type O₂, O₂, 0-25 Vol.%, Oxygen sensor; 5150235-00A — BUSENS D, type H₂S, H₂S, 0-30 ppm, Hydrogen sulfide sensor; 5150236-00A — BUSENS D, type H₂S, H₂S, 0-50/100 ppm, Hydrogen sulfide sensor; 5150237-00A — BUSENS D, type CO, CO, 0-100/0-500 ppm, Carbon monoxide sensor; 5150238-00A — BUSENS D, type H₂, H₂, 0-1000 ppm, Hydrogen ppm sensor; 5150239-00A — BUSENS D, type H₂, H₂, 0-100 %LEL, Hydrogen LEL sensor; 5101163-00A — BUSENS D, type NO, NO, 0-100 ppm, Nitric oxide sensor; 5101164-00A — BUSENS D, type NO₂, NO₂, 0-20 ppm, Nitrogen dioxide sensor
Non-main Row Source NoteManufacturer page 3 row identities are retained; compatibility is not inferred across rows.
Dimension DiscrepancyUnresolved source discrepancy: page 2 table gives height 179 mm; page 4 drawing gives overall height 218 mm. Both source roles are retained; no normalized overall height is asserted.
Image RoleThe only native product image in this ST450 EC source is shared by the family; it is not claimed as an exact SKU- or gas-specific photo.

Compatibility

    Manufacturer-listed system references

    Compatible systems
    CGD50/500, CGS50/500

    Check the original document for configuration, installation conditions and restrictions.

    Original manufacturer documents and sources

    Accessories

    • 5150227-00A — Splash guard, Sensor protection against splash water
    • 5150228-00A — Inline flow adapter, Inline flow adapter for sample applications, connection 2×6 mm, SS
    • 5150226-00A — Protective hood, Protective hood SS, for optimal protection in “wet” protection areas, dim. 315×300×138 mm
    • 5150231-00A — Isolation set EMC/RFI, Isolation board, 160×160 mm
    • 5150225-00A — Protective bracket, SS bracket, extra protection for use in warehouses