Connecting Global Safety Technology

ECOTOX Portable Single Gas Detector (Hydrogen Sulfide (H2S), 0–100 ppm, 1225300 I)

Original manufacturer
Consilium / Salwico
Name
ECOTOX Portable Single Gas Detector (Hydrogen Sulfide (H2S), 0–100 ppm, 1225300 I)
Model
ECOTOX
Part number
1225300 I

Supply availability and delivery time require confirmation. A catalog reference does not imply stock.

Specifications

Manufacturer approvals / certificationsATEX II 2 G Ex ia IIC T4 Gb IECEx Ex ia IIC T4 Gb
Part No.1225300 I
ModelECOTOX
Product TypePortable single gas detector
Compatible SystemsGS5000; SW3020; CS1; BuControl; BuTouv.
Gas TypeHydrogen Sulfide (H2S)
Measuring Range0–100 ppm
Low Alarm10 ppm
High Alarm15 ppm
Operating Temperature-20 °C to +50 °C
Relative Humidity15–90% RH, non-condensing
VersionI: On / Off function, in case the detector is not used it can be switched off
Life Time24 months at 5 minutes alarm per day
OperationContinuous after activation; On/Off is ordering option I
Dimensions82 × 56 × 42 mm
WeightApproximately 100 g
HousingPC and TPU
Measuring PrincipleElectrochemical sensor
BatteryLithium
Storage Temperature0 °C to +20 °C
DisplayLC display: alarm values, remaining lifetime and status
Alarm SettingsTwo settings: low and high alarm
AlarmsBuzzer >90 dB at 30 cm; red flashing LEDs and display; vibration
MountingHeavy-duty crocodile carrying clip
Ce MarkingPrinted ATEX Directive 2018/34/EU and EMC Directive 2014/30/EU; source wording retained, current conformity not verified.
ManufacturerConsilium Safety Netherlands B.V.
Atex ApprovalATEX II 2 G Ex ia IIC T4 Gb
Iecex ApprovalIECEx Ex ia IIC T4 Gb
Manufacturer Test-gas Catalogue (separate Items)9990522: CO detector test gas, 100 ppm CO in air; 9990507: H2S detector, 10 ppm alarm, 25 ppm H2S in N2; 9990524: N2 test gas for O2 detector; 9990540: H2S detector, 1.6 ppm alarm, 10 ppm H2S in N2. Gas-specific test gases are separate items.

Compatibility

  • GS5000
  • SW3020
  • CS1
  • BuControl
  • BuTouv

Manufacturer-listed system references

Compatible systems
GS5000; SW3020; CS1; BuControl; BuTouv.

Check the original document for configuration, installation conditions and restrictions.

Original manufacturer documents and sources

Accessories

  • Test gas for the CO detector, 100 ppm CO in air.
  • Test gas for the H2S detector, 10 ppm alarm.
  • Test gas (N2) for the O2 detector.
  • Test gas for the H2S detector, 1.6 ppm alarm.