Connecting Global Safety Technology

CM-L-G with housing

Original manufacturer
Consilium / Salwico
Name
CM-L-G with housing
Model
CM-L-G
Part number
5100247-00A

Supply availability and delivery time require confirmation. A catalog reference does not imply stock.

Specifications

Manufacturer approvals / certificationsNot provided by manufacturer
Manufacturer Article Number5100247-00A
Operating Voltage19-30 VDC
Current Consumption (at 24 V)70 mA
Loop Output Nominal Voltage35 VDC
Loop Maximum Output Current400 mA (< 15 minutes)
Loop Continuous Output Current200 mA
Max. No. Of Loop Units20
Cable Terminals2.5 mm²
Operating Temperature-40 °C to +70 °C
Storage Temperature-50 °C to +70 °C
Relative Humidity≤ 95 % RH non-condensing
Addressing MethodDIP switch
MaterialNylon 6.6
Weight (with Housing)140 g ± 5%
Colour HousingBlack (RAL 9005)
Colour ShellGray (RAL 7042)
Spare Part No. Cm-l-g5100245-00
Spare Part No. For Housing5100102-01
Loop Cable RequirementSee the Installation & Commissioning manual
Compatible Loop UnitsAll gas loop units that communicates with the IDAxt protocol
Compatible SystemCGD50/500
Dip Switch 8Always ON
Physical Address SelectionBinary address on the Backbone Bus via DIP poles 1–7; addresses 63–74 are allowed only under the specific conditions in the installation manual.
MountingHorizontal 35 mm DIN rail
Loop ConnectionsOriginal terminal table: loop A+ = 11, A− = 12; loop B+ = 13, B− = 14. Follow the original connection drawing.
Alarm / Fault IndicatorsALARM red steady: one or more gas alarms; off: no alarms. FAULT yellow steady: one or more faults; yellow flashing: booting or re-scanning the loop; off: no faults.
Ps Power-supply IndicatorGreen: operational without power fault. Yellow steady: operational with one power fault, communication with loop units continues. Yellow flashing 0.5 s on/0.5 s off: boot loader during firmware download; the loop unit cannot communicate. Off: quarantine mode.
Com Backbone IndicatorGreen steady: communication and received configuration. Green flashing 0.5 s on/0.5 s off: communication, awaiting configuration. Yellow steady: no communication. Yellow flashing 0.5 s on/0.5 s off: firmware transfer; 1 s on/0.5 s off: quarantine.
Transfer / Fault DiagnosticsPS yellow and COM green both flashing 0.5 s on/0.5 s off: software upload/download. All LEDs flashing: all DIP switches OFF or all ON; set to project documentation. Consult control-panel fault alarms and the CGD500 Installation or Service & Maintenance manual.
Original Mounting Dimensions99 mm vertical; 114.5 mm side horizontal; 29 mm overall front width; 22.5 mm front subdimension. See the original drawing for orientation and clearances.

Compatibility

  • CGD50/500; IDAxt gas loop units; follow the exact original installation manual.

Accessories

  • Spare CM-L-G PCB module 5100245-00; housing spare 5100102-01, as printed in the original parts table.
  • Loop cable selection and addresses63–74 require the original Installation & Commissioning manual.