Connecting Global Safety Technology

Surge Prot M H Surge Protection Module

Original manufacturer
Consilium / Salwico
Name
Surge Prot M H Surge Protection Module
Model
Surge Prot M H
Part number
5100421-00A

Supply availability and delivery time require confirmation. A catalog reference does not imply stock.

Specifications

Manufacturer approvals / certificationsNot provided by manufacturer
Manufacturer Article Number5100421-00A
Operating Voltage Range19-30 VDC
Max. Supply Current – Psu1 In & Psu2 In8 A + 8 A
Max. Load Current – Psu1 Out & Psu2 Out0.7 A + 0.7 A
Quiescent Current Consumption (at 24v)42 mA
Cable Terminals2.5 mm²
Operating Temperature Range-5°C to +55°C
Weight (with Housing)115g ±5%
Spare Part No. (without Housing)5100420-00A
Fuse F101/f10210A Fast-Acting
Manufacturer-listed SystemsSalwico Cargo, Salwico Cruise, Salwico Ro/Pax, Salwico Workboat, Salwico Yacht, CFD5000 (2016 C M document)
FunctionsSurge-protected BBI power inputs; BBE RS485 Repeater terminal board; electronic short-circuit-protected Control/Repeater outputs. Functions can be used together or individually
Output Supervision / Isolation RestrictionProtected outputs are NOT supervised. Use only where electrical isolation between devices is not required
Rs485 TerminationBuilt-in 120 Ω terminators. S101 controls BBE; S102 controls BBI; see original tables and Installation Manual for application examples
S101 / Bbe SwitchesPole 1: BBE-1; pole 2: BBE-2. Each pole ON activates its terminator; OFF deactivates
S102 / Bbi SwitchesPole 1: BBI-1; pole 2: BBI-2. Each pole ON activates its terminator; OFF deactivates
Power ConnectorsPSU1: 11 IN 8A+, 12 OUT 0.7A+, 13 minus. PSU2: 21 IN 8A+, 22 OUT 0.7A+, 23 minus
Data / Bus Connectors31 D+/32 D-: BBE-1; 41 D+/42 D-: BBE-2; 33 plus: BBU; 43: ground. Retain original p2 connection figure
Psu Input IndicatorsGreen: OK. Yellow: F101 (PSU1) or F102 (PSU2) blown. No light: corresponding input supply absent
Psu Output IndicatorsGreen: OK. Yellow: corresponding output fault/overload. No light: respective PSU1 IN/F101 or PSU2 IN/F102 supply/fuse fault, as listed in this 2016 M source
Bbe Communication IndicatorsBBE-1 and BBE-2 Tx/Rx: green OK; no light means no communication
Dimensions99 mm height ×114 mm depth; 24 mm overall width with 18 mm front width and 7 mm mounting subdimension
Mounting / Required InstructionsHorizontal 35 mm DIN rail. Refer to system Installation Manual for assembly, common terms and RS485 termination examples

Compatibility

  • Requires technical confirmation; manufacturer compatibility evidence is not provided.

Accessories

  • Not provided by manufacturer

Original documents & sources

Source pages