Connecting Global Safety Technology

Surge Prot M H Surge Protection Module

Original manufacturer
Consilium / Salwico
Name
Surge Prot M H Surge Protection Module
Model
Surge Prot M H
Part number
5100421-02A

Supply availability and delivery time require confirmation. A catalog reference does not imply stock.

Specifications

Manufacturer approvals / certificationsNot provided by manufacturer
Manufacturer Article Number5100421-02A
Operating Voltage Range19-30 V DC
Max. Supply Current (psu1 In / Psu2 In)8 A + 8 A
Max. Load Current (psu1 Out / Psu2 Out)0.7 A + 0.7 A
Quiescent Current Consumption (at 24 V)42 mA
Cable Terminals2.5 mm²
Operating Temperature Range-40 °C to +70 °C (OT4)
Switch-on Extended Operating Temperature+15 °C during 10 min (ST1)
Temperature Classes According ToEN 50155:2017
Weight (with Housing)115 g ± 5%
Spare Part Number (without Housing)5100420-00A
Fuse F101/f10210A Fast-Acting
Manufacturer-listed SystemsTS1000; CFD500 T
Functional ScopeSurge-protected BBI power inputs; BBE RS485 repeater terminal board; electronically short-circuit-protected Control/Repeater outputs
Use / Supervision LimitsFunctions may be used together or individually; for applications without an electrical-isolation requirement between devices. Protected Control/Repeater output is not supervised
Rs485 TerminationBuilt-in 120 ohm terminators; follow Installation Manual for network examples and recommendations
Bbe Termination SwitchesS101 pole 1: BBE-1; pole 2: BBE-2. ON activates termination; OFF deactivates
Bbi Termination SwitchesS102 pole 1: BBI-1; pole 2: BBI-2. ON activates termination; OFF deactivates
Psu ConnectorsPSU1: 11 IN 8A+, 12 OUT 0.7A+, 13 minus. PSU2: 21 IN 8A+, 22 OUT 0.7A+, 23 minus
Bbe / Bbu ConnectorsBBE-1: 31 D+, 32 D-; BBU: 33 positive. BBE-2: 41 D+, 42 D-; 43 ground
MountingMount on a horizontal 35 mm DIN rail
Dimensions24 mm width; 99 mm height; 114 mm depth (original drawing also marks 18 mm and 7 mm subdimensions)
Status IndicatorsPSU IN/OUT and BBE Tx/Rx status shown; green indicates OK. See original indicator table for fuse and overload diagnostics

Compatibility

  • Requires technical confirmation; manufacturer compatibility evidence is not provided.

Accessories

  • Not provided by manufacturer

Original documents & sources

Source pages