Connecting Global Safety Technology

CD-S Type A Alarm Sounder

Original manufacturer
Consilium / Salwico
Name
CD-S Type A Alarm Sounder
Model
CD-S
Part number
5100626-00B

Supply availability and delivery time require confirmation. A catalog reference does not imply stock.

Specifications

Manufacturer approvals / certificationsNot provided by manufacturer
Manufacturer Article Number5100626-00B
Power Supply16 - 38 VDC
Operating Current0.1 mA
Alarm Current3.5 - 3.8 mA
Frequency Range800 - 2400 Hz (depends on the selected tone)
Sound Output74-83 dB(A) at 1 m (depends on the selected tone)
Sound Output Tolerance±3 dB(A)
Operating Temperature-25 °C to +55 °C
Storage Temperature-40 °C to +70 °C
Relative Humidity≤ 95 % RH non-condensing
Ingress ProtectionIP22
MaterialFR Polyamide
Fire Behavior Of MaterialsHLR3, I2/F2 and NFPA 130
ColourRAL 9003 White
Weight0.027 kg
Source Conformity StatementEN 54-3:2014 + A1:2019
Rohs DirectiveRoHS 2
EnvironmentENV1
Detector Compatibility / Dip 4-5Types1 RDJ/IA/OA and2 EV-PP (IDA): ON/OFF; type3 NS: OFF/ON; type4 EV-P/H incl. CN-PYH: ON/ON; type5 CS-PYH and6 CD-PH RIL: OFF/ON. Use exact detector lists on original p2
Compatible Base SelectionCD-B 5101509-00A; CD-B SCI 5101510-00A; UB-6 044445; UB-6 SCI 5200313-00A; UB-6 PA66 5100449-00A
Tone Selection / Dip 1-31: 2400Hz continuous,83dB(A),OFF/OFF/OFF,marine recommended; 2:800-1105Hz alternating at2Hz,81dB(A),ON/OFF/OFF,building recommended; 3:1105Hz 1sON/1sOFF,74dB(A),OFF/ON/OFF. 4-16 unused; values at1m, +/-3dB(A)
Mounting / Cable ProtectionRemove base cutout with knife/pliers,attach sounder,wire then mount on flat surface. Avoid trapped cables: CD-B route between screws and refit protective plastic; UB-6 secure with suitable fixing compound
Cable FunctionsRed=sounder(+); black=sounder(-); yellow=sounder control. Match detector type and SCI-specific diagram; connections are not interchangeable
Type1/2 Wiring AlternativesAlt1: control1, sounder(+)/loop(+)3, sounder(-)/loop(-)6. Alt2: control/sounder(+)1, loop(+)3, sounder(-)4, loop(-)6; follow original p3-4 diagrams
Type3/4 Wiring: Without / With SciWithout SCI: sounder(+)/loop(+)1, control3, sounder(-)/loop(-)6. With SCI: sounder(+)/loop IN(+)/OUT(+)1, control3, loop IN(-)4, OUT(-)5, sounder(-)6
Type5/6 WiringType5: sounder(+)/loop(+)3, control/sounder(-)4, loop IN(-)5, OUT(-)6. Type6: sounder(+)/loop(+)1, control/sounder(-)3, loop IN(-)5, OUT(-)6
Sum-2 ReplacementSet detector-type DIP first. Types1/2: red+yellow to P/1,black to R/4. Types3/4: red to P/1,black+yellow to L/3. Alternatively rewire fully using original connection examples

Compatibility

  • Requires technical confirmation; manufacturer compatibility evidence is not provided.

Accessories

  • Not provided by manufacturer