IC44 SS WP Stainless-Steel Weatherproof I/O Interface Module
- Original manufacturer
- Consilium / Salwico
- Name
- IC44 SS WP Stainless-Steel Weatherproof I/O Interface Module
- Model
- IC44 SS WP
- Part number
- 5100782-00A
Supply availability and delivery time require confirmation. A catalog reference does not imply stock.
Specifications
| Manufacturer approvals / certifications | Not provided by manufacturer |
|---|---|
| Ingress Protection | IP66 |
| Relative Humidity | ≤ 95 % RH non-condensing |
| Ambient Temperature | -40°C to +70°C |
| Cable Gland | M20 for cable ø 6–13mm |
| Cable Gland Material | Nickel plated brass |
| Cable Terminals | 2.5 mm2 |
| Enclosure Material | Stainless steel AISI 304 |
| Gasket Material | Polyurethane and silicone |
| Colour | Polished surface |
| Weight | ≈1 kg |
| Certification | EN 50155 |
| External 24 Vdc Nominal Voltage | 24 VDC |
| External 24 Vdc Working Voltage | 19 - 30 VDC |
| External 24 Vdc Max Current | 100 mA |
| External 24 Vdc Nominal Power Output | 24 VDC, 80 mA |
| External 24 Vdc Max Input Load | 15 mA per input. Pulsed. |
| External 24 Vdc Input Pulse Length | 100 ms |
| Loop-powered Nominal Voltage | Not provided by manufacturer |
| Loop-powered Working Voltage | Not provided by manufacturer |
| Loop-powered Max Current | Not provided by manufacturer |
| Loop-powered Nominal Power Output | Not provided by manufacturer |
| Loop-powered Max Input Load | 5 mA per input. Pulsed. |
| Loop-powered Input Pulse Length | 8 ms |
| Inputs | 4 inputs for closing contacts or NPN/PNP proximity switches |
| Relay Output Rating | 4 pcs 2-pole relay contacts, max 30 VDC, 1A |
| Power Output | 24 VDC, 80 mA |
| Loop Nominal Voltage | 35 VDC |
| Loop Working Voltage | 22 - 38 VDC |
| Loop Current Consumption | 0.3 mA |
| Input End Of Line Resistor | 30kΩ (Included) |
| Sw2 Dip 8 Requirement | SW2 DIP 8 must always be ON. |
| Address Switch | SW1 sets the loop address. |
| External 24 Vdc Input Terminals | 13-16, 18-36 VDC, optional |
| Isolated 24 Vdc Output Terminals | 21-22, max 5 mA for local indicators; active only with external 24 VDC input on 13-16 |
| Output Terminals | 23-46, NC/NO output 1 to 4 |
| External Earth Condition | Connect the enclosure external earth connection to earth; see the Installation & Commissioning manual. |
| Source Datasheet | Data sheet no. 5100782-00A_IC44 SS WP_T_EN_2019_B |
| Specification Change Notice | The specifications described herein are subject to change without notice. |
| Proximity Switch Supply Condition | NOTE! The use of proximity switches requires external 24 VDC supply. |
| Body Width | 150 mm |
| Body Height | 150 mm |
| Body Depth | 80 mm |
| Overall Width | 200 mm |
| Overall Height | 196 mm |
| Mount Width | 175 mm |
| Mount Height | 106 mm |
| Wall Mounting Holes | 4 holes; max screw thread M8 |
| External Earth Connection Thread | M6 |
| Installation Caution | CAUTION! Do not use electrical screwdriver. Maximum torque 2 Nm. |
| Table 1. Id For Different Operation Modes Set By Sw2 Dip 1 To 5 (operation-modes) — Row 1 — Mode | 1 |
| Table 1. Id For Different Operation Modes Set By Sw2 Dip 1 To 5 (operation-modes) — Row 1 — Function | 2 inputs and 2 outputs |
| Table 1. Id For Different Operation Modes Set By Sw2 Dip 1 To 5 (operation-modes) — Row 1 — Example | Emulates control unit CM-2x |
| Table 1. Id For Different Operation Modes Set By Sw2 Dip 1 To 5 (operation-modes) — Row 2 — Mode | 2 |
| Table 1. Id For Different Operation Modes Set By Sw2 Dip 1 To 5 (operation-modes) — Row 2 — Function | 4 inputs and 4 outputs |
| Table 1. Id For Different Operation Modes Set By Sw2 Dip 1 To 5 (operation-modes) — Row 2 — Example | Emulates control unit CM-4x |
| Sw2 Function Settings (sw2-function-settings) — Row 1 — Sw2 Dip | 6 |
| Sw2 Function Settings (sw2-function-settings) — Row 1 — Setting | ON |
| Sw2 Function Settings (sw2-function-settings) — Row 1 — Function | Must be set when external 24VDC power supply is used. |
| Sw2 Function Settings (sw2-function-settings) — Row 2 — Sw2 Dip | 7 |
| Sw2 Function Settings (sw2-function-settings) — Row 2 — Function | Not used |
| Terminal Connections (terminal-connections) — Row 1 — Terminal Range | 1-12 and 47-50 |
| Terminal Connections (terminal-connections) — Row 1 — Signal | IN+ |
| Terminal Connections (terminal-connections) — Row 1 — Connection | Input 1 to 4 |
| Terminal Connections (terminal-connections) — Row 2 — Terminal Range | 1-12 and 47-50 |
| Terminal Connections (terminal-connections) — Row 2 — Signal | IN- |
| Terminal Connections (terminal-connections) — Row 2 — Connection | Input 1 to 4 |
| Terminal Connections (terminal-connections) — Row 3 — Terminal Range | 1-12 and 47-50 |
| Terminal Connections (terminal-connections) — Row 3 — Signal | SIG |
| Terminal Connections (terminal-connections) — Row 3 — Connection | Input 1 to 4 |
| Terminal Connections (terminal-connections) — Row 4 — Terminal Range | 1-12 and 47-50 |
| Terminal Connections (terminal-connections) — Row 4 — Signal | IND * |
| Terminal Connections (terminal-connections) — Row 4 — Connection | Input 1 to 4 |
| Terminal Connections (terminal-connections) — Row 5 — Terminal Range | 13-16 |
| Terminal Connections (terminal-connections) — Row 5 — Signal | + |
| Terminal Connections (terminal-connections) — Row 5 — Connection | External 24VDC input (18-36VDC). Optional. |
| Terminal Connections (terminal-connections) — Row 6 — Terminal Range | 13-16 |
| Terminal Connections (terminal-connections) — Row 6 — Signal | - |
| Terminal Connections (terminal-connections) — Row 6 — Connection | External 24VDC input (18-36VDC). Optional. |
| Terminal Connections (terminal-connections) — Row 7 — Terminal Range | 17 |
| Terminal Connections (terminal-connections) — Row 7 — Signal | A+ |
| Terminal Connections (terminal-connections) — Row 7 — Connection | Loop IN & Loop OUT |
| Terminal Connections (terminal-connections) — Row 8 — Terminal Range | 18 |
| Terminal Connections (terminal-connections) — Row 8 — Signal | A- |
| Terminal Connections (terminal-connections) — Row 8 — Connection | Loop IN & Loop OUT |
| Terminal Connections (terminal-connections) — Row 9 — Terminal Range | 21-22 |
| Terminal Connections (terminal-connections) — Row 9 — Signal | + |
| Terminal Connections (terminal-connections) — Row 9 — Connection | Isolated 24VDC output (for local indications). Max 5 mA for local indicators. Note: Only active when external 24VDC input is connected to 13-16. |
| Terminal Connections (terminal-connections) — Row 10 — Terminal Range | 21-22 |
| Terminal Connections (terminal-connections) — Row 10 — Signal | - |
| Terminal Connections (terminal-connections) — Row 10 — Connection | Isolated 24VDC output (for local indications). Max 5 mA for local indicators. Note: Only active when external 24VDC input is connected to 13-16. |
| Terminal Connections (terminal-connections) — Row 11 — Terminal Range | 23-46 |
| Terminal Connections (terminal-connections) — Row 11 — Signal | C |
| Terminal Connections (terminal-connections) — Row 11 — Connection | Output 1 to 4 |
| Terminal Connections (terminal-connections) — Row 12 — Terminal Range | 23-46 |
| Terminal Connections (terminal-connections) — Row 12 — Signal | NC |
| Terminal Connections (terminal-connections) — Row 12 — Connection | Output 1 to 4 |
| Terminal Connections (terminal-connections) — Row 13 — Terminal Range | 23-46 |
| Terminal Connections (terminal-connections) — Row 13 — Signal | NO |
| Terminal Connections (terminal-connections) — Row 13 — Connection | Output 1 to 4 |
| System Association | TS1000 |
Compatibility
Manufacturer-listed system references
- System association
- TS1000
Check the original document for configuration, installation conditions and restrictions.
Accessories
- Not provided by manufacturer
Original documents & sources
Source pages
Original manufacturer data retained. Product enquiry and technical sourcing by MAXONE Marine. Last reviewed: 2026-10-25T17:58:43.047396+00:00.