Connecting Global Safety Technology

PG11 C3H8 Gas Detector (0-100 %VOL)

Original manufacturer
Consilium / Salwico
Name
PG11 C3H8 Gas Detector (0-100 %VOL)
Model
PG11
Part number
5101558-00

Supply availability and delivery time require confirmation. A catalog reference does not imply stock.

Specifications

Manufacturer approvals / certificationsATEX / IECEx markings; Presafe 20 ATEX 67361X / IECEx PRE 20.0061X. Current certificate validity unknown.
Manufacturer Article Number5101558-00
Configured Gas / RangeC3H8; 0-100 %VOL
Printed Order DescriptionPG11 Point C3H8, WH, 0-100%VOL
Compatible SystemsCGD50/500; CGS50/500.
DetectionSolid-state infrared, temperature compensated.
Accuracy±3% of full scale over the whole operating temperature range.
Response T902 s with the included environment shield; 1 s without shield.
Pressure CorrectionAtmospheric-pressure calibration; reading changes 1% per kPa deviation from atmospheric pressure.
Operating Supply18–50 V DC; average power <3 W.
Startup CurrentSoft boot-up keeps rush current below 1 A.
Cable / Terminals3 wires, 0.5–2.5 mm²; terminals maximum 2.5 mm².
Standard Cable GlandPolyamide M20 Ex e; printed gland inner diameter 5.5–13 mm.
Optional Cable EntriesM25, 1/2 inch NPT or 3/4 inch NPT on request.
Measurement Signal4–20 mA; terminal 3 green is 0–20 mA analogue safety signal with HART overlay.
Digital CommunicationRS-485 Modbus RTU: terminal 4 yellow A, terminal 5 grey B.
Power / Earth Terminals1 white: printed +24 V DC supply; 2 brown: 0 V return. Yellow/green: internal earth.
Operating / StorageOperating −40 to +75 °C; storage −60 to +75 °C.
Environment70–130 kPa; 0–100% RH; IP66/IP67. Included shield protects against splash and dirt.
Housing / Cover316L stainless housing; composite back cover standard, steel optional; black/silver.
Weight / Dimensions3 kg ±5%; L×W×H: 238×120×102 mm.
Printed Expected Lifetime15 years, as printed in the source datasheet.
Printed Standards / Safety ScopeATEX / IECEx markings; Presafe 20 ATEX 67361X / IECEx PRE 20.0061X. Current certificate validity unknown.
Printed Ex MarkingsATEX: II 2 G Ex db eb ib IIC T5 Gb / Ex db ib IIC T5 Gb. IECEx: Ex db eb ib IIC T5 Gb / Ex db ib IIC T5 Gb.
Printed Ex Ambient Scope−55≤Tamb≤+75 °C in the IECEx marking. Normal operating limit remains −40 to +75 °C.
Accessories5101518-00 bump-test housing; 5101594-00 Gas Free test kit; 5101580-00 flow house; 5101587-00 cleaning kit; 5101585-00 mosquito net.
Green IndicationSteady: normal. Blinking: cleaning/maintenance request OR outside-temperature-rating indication.
Yellow IndicationSteady: service/function check. Blinking: fault or booting; no measurement.
Red / Alarm IndicationSteady Alarm 1: default 20% full scale; blinking Alarm 2: default 50% full scale. Both non-latching.
Mounting / ClearanceHorizontal only; at least 6 cm around and 9 cm in front of the sensor head for test equipment.
Hazardous-area InstallationFollow PG11/PGE11 Operating Manual 022-80036-OM for hazardous-area installation.
Original Installation DrawingsFour-page original retains terminal/hole-pattern drawings and external-earth point. Refer to installation manual for details.

Compatibility

  • CGD50/500
  • CGS50/500

Accessories

  • Bump test housing: 5101518-00
  • Gas test kit Gas Free: 5101594-00
  • Flow house: 5101580-00
  • Cleaning kit: 5101587-00
  • Mosquito net: 5101585-00