Connecting Global Safety Technology

ST350 Gas Detector (Carbon disulfide (CS2), 0-300 ppm, SS316, LCD)

Original manufacturer
Consilium / Salwico
Name
ST350 Gas Detector (Carbon disulfide (CS2), 0-300 ppm, SS316, LCD)
Model
ST350
Part number
5150020-00A

Supply availability and delivery time require confirmation. A catalog reference does not imply stock.

Specifications

Manufacturer approvals / certificationsATEX Directive 2014/34/EU; current validity unknown. EMC Directive 2014/30/EU; current validity unknown. IECEx; current validity unknown.
Part No.5150020-00A
ModelST350
Product TypeGas detector.
Compatible SystemsCGD50/500; CGS50/500.
Gas TypeCarbon disulfide (CS2)
Range0-300 ppm
MaterialSS316
VersionLCD
Sensor TypeBUSENS D, type SCV.
CalibrationFamily default calibration: Toluene (SCV). Other calibrations must be specified when ordered. Configured gas/range are listed separately.
General DescriptionAll-round industrial gas detector with replaceable BUSENS D gas sensor; SCV and SCF sensor versions.
Family Detection ScopeAromatic hydrocarbons and synthetic refrigerant gases (H)CFKs and HFKs.
Scv Sensor SuitabilityAromatic hydrocarbons at ppm level, including toluene and xylene, and chemical-industry gases such as carbon disulfide.
Scf Sensor SuitabilitySynthetic refrigerants (H)CFKs and HFKs, including R134a, R407c and R1234yf.
Atex / Iecex ScopeATEX / IECEx approved; current certificate validity unknown.
Control InterfaceFamily LCD-version feature: Capacitive key control similar to a touchscreen; no additional tools required.
Self-diagnosticsIncluded.
SplashguardIncluded.
User MenuFamily LCD-version feature: Zero and span calibration, alarm set-point adjustment, set-point display, diagnostics, and 4-20 mA output simulation.
Password ProtectionFamily LCD-version feature: User menu secured with a password.
DisplayDigital graphic display with backlight.
Status LedGreen: OK; red: alarm; yellow: system failure.
Power Supply17.5-24 V DC; maximum 120 mA.
Load ImpedanceMaximum 400 Ω at 24 V DC.
Outputs4-20 mA; RS485 Modbus RTU half-duplex; 2 mA system failure; >20 mA over range.
Signal Cable3-wire shielded; 0.75-2.5 mm².
Cable GlandSS housing: SS; M20×1.5.
Operating Temperature-10 °C to +50 °C.
Ingress ProtectionEnclosure IP66; sensor IP6X. IP ratings do not imply gas detection during or after exposure to those conditions.
Relative Humidity15-95% RH, non-condensing.
Pressure Range700 to 1300 hPa.
Enclosure MaterialSS316.
Dimensions179 × 189 × 107 mm (H × W × D).
Weight2.6 kg ±5% (SS316).
Enclosure Gas SensorSS316.
CertificationATEX Directive 2014/34/EU; EMC Directive 2014/30/EU; current validity unknown.
Atex ApprovalsII 2G Ex d IIC T6 Gb; II 2D Ex tb IIIC T85°C Db.
Iecex ApprovalsEx d IIC T6 Gb; Ex tb IIIC T85°C Db.
MountingVertical position with sensor pointing downwards.
Installation ClearanceAt least 11 cm free space below the sensor head for splashguard removal and bump-test hose connection.
ApplicationsRefrigeration; soil remediation; painting and printing ink industries; spraying booths and dry cabins; shipping; storage of dangerous goods; chemical industry.
Optional AccessoriesInline flow adapter 5150228-00A; protective hood 5150226-00A; isolation set EMC/RFI 5150231-00A; protective bracket 5150225-00A; conical collector hood 5150230-00A. Optional; not assumed standard.
Spare Gas SensorsBUSENS D SCV 5150232-00A and BUSENS D SCF 5150233-00A; range/calibration dependent.

Compatibility

  • CGD50/500
  • CGS50/500

Accessories

  • Inline flow adapter 5150228-00A; optional.
  • Protective hood 5150226-00A; optional.
  • Isolation set EMC/RFI 5150231-00A; optional.
  • Protective bracket 5150225-00A; optional.
  • Conical collector hood 5150230-00A; optional.

Original documents & sources