Specifications
| Manufacturer approvals / certifications | Compact/remote: II 2G Ex d IIC T6 Gb; II 2D Ex tb IIIC T85°C Db. Remote HT: II 2G Ex d IIC T3 Gb; II 2D Ex tb IIIC T200°C Db. Compact/remote: Ex d IIC T6 Gb; Ex tb IIIC T85°C Db. Remote HT: Ex d IIC T3 Gb; Ex tb IIIC T200°C Db. |
|---|---|
| Part No. | 5150209-00A |
| Order-table Application | Methane |
| Order-table Gas (source Footnote Marker) | CH4 * |
| Order-table Sensor | NDIR |
| Order-table Range | 0-100 %LEL |
| Material | Aluminium |
| Version | LCD |
| Model | ST650 EX |
| Product Type | Gas detector. |
| Compatible Systems | CGD50/500; CGS50/500. |
| General Description | The ST650 EX is an all-round gas detector which functions well under the most difficult circumstances. The sensor is available in various versions, such as a catalytic flammable gas sensor, Infrared (NDIR) and a Thermal Conductivity sensor (TCD). The sensor has a long life-span, which achieves an optimal cost of ownership. |
| Family Display (optional) | Digital graphic display with backlight (optional). |
| Status Led | Green: OK; red: alarm; yellow: system failure. |
| Family Calibration (order Requirement) | Standard: Methane. Also available for Propane, Butane, Hydrogen, Methanol, Ethanol, Kerosene, Gasoline, Toluene, Hexane, Ammonia, Acetic acid, and more (calibration to be specified when ordered). |
| Gas Type | Combustible gases and vapours; exact order-table gas is listed separately for each SKU. |
| Sensor Type | Catalytic bead sensor, Infrared (NDIR), or Thermal conductivity sensor (TCD); exact order-table sensor is listed separately for each SKU. |
| Order-table Footnote | * Standard calibration. Other calibrations to be specified when ordered. |
| Family Range | 0-100 %LEL, 0-10 %LEL, 0-100 Vol.% (depending on gas type, sensor type, and calibration). |
| Power Supply | 17.5-24 V DC (max. 120 mA). |
| Outputs | 4-20 mA; RS485 Modbus RTU (half-duplex); 2 mA system failure; >20 mA over range. |
| Signal Cable | 3-wire shielded; 0.75-2.5 mm². |
| Cable Gland (by Enclosure Material) | Aluminium housing: Brass; SS housing: SS (thread M20x1.5). |
| Cable Dimension | Ø max. 16 mm (incl. shielding). |
| Load Impedance | Max. 400 Ω at 24 V DC. |
| Family Temperature Limits By Application/sensor | Standard: -20 °C to +60 °C. IR versions: -20 °C to +50 °C. Remote HT: -20 °C to +120 °C. |
| Ingress Protection | Enclosure IP66; sensor IP6X. IP ratings do not imply that the equipment will detect gas during and after exposure to those conditions. |
| Relative Humidity | 15-95% RH (non-condensing). |
| Pressure Range | 700 to 1300 hPa. |
| Enclosure Material | Aluminium with coating, optional SS. |
| Dimensions | 179 × 189 × 107 mm (H × W × D). |
| Weight | 1.5 kg ± 5% (Al); 2.6 kg ± 5% (SS). |
| Enclosure Gas Sensor | SS 316. |
| Specific Conditions Of Use | Refer to ATEX certificate. |
| Certification Marking And Directives | CE mark shown with 0344 beside it; ATEX (Directive 2014/34/EU); Electromagnetic Compatibility (Directive 2014/30/EU); 0344 is not identified as a certificate ID in the source; current validity unknown. |
| Atex Approvals | Compact/remote: II 2G Ex d IIC T6 Gb; II 2D Ex tb IIIC T85°C Db. Remote HT: II 2G Ex d IIC T3 Gb; II 2D Ex tb IIIC T200°C Db. |
| Iecex Approvals | Compact/remote: Ex d IIC T6 Gb; Ex tb IIIC T85°C Db. Remote HT: Ex d IIC T3 Gb; Ex tb IIIC T200°C Db. |
| Certification Note | More information can be found in the sensor datasheets. Current certificate validity is unknown. |
| Sensor Differences | Measuring range; resistance to silicone poisoning; detects hydrogen; affected by hazardous chemical environments; detection in anaerobic / inert conditions; no sensor burn-out at high concentrations; sensor lifetime. |
| Silicone Poisoning Resistance | Catalytic: no; TCD: limited; NDIR: yes. |
| Hydrogen Detection | Catalytic: up to 100 %LEL; TCD: up to 100 Vol.%; NDIR: no. |
| Hazardous Chemical Environments | Catalytic: yes; TCD: limited; NDIR: no. |
| Anaerobic / Inert Detection | Catalytic: no; TCD: yes; NDIR: yes. |
| No Sensor Burn-out At High Concentrations (family Comparison) | Catalytic: no; TCD: yes; NDIR: yes. |
| Sensor Lifetime | Catalytic: 3 years; TCD: 3 years; NDIR: 4-6 years. |
| Sensor-selection Safety Note | Special care should be taken when selecting sensors for certain environments. If uncertain, consult your local Consilium representative. |
| Mounting | Mount the detector in a vertical position, with the sensor pointing downwards. |
| Installation Clearance | Leave at least 11 cm free space below the sensor head to ensure the splashguard can be removed during sensor exchange. This also allows connection of a hose for bump tests. |
| Connections | Follow the original manufacturer connection diagram on source page 5; terminal allocation is not reproduced here. |
| Remote Application (family Remote Condition) | Remote sensors are ideal where gases ascend. Cable lengths up to 150 metres are supported between transmitter and sensor (depending on type). |
| Touch-style Control (family Lcd-version Feature) | Capacitive key control similar to a touchscreen; no additional tools required. |
| Self-diagnostics | Included. |
| Splashguard | Included. |
| User Menu (family Lcd-version Feature) | Zero and span calibration; alarm set-point adjustment; set-point display; diagnostics; 4-20 mA output simulation. |
| Password Protection (family Lcd-version Feature) | User menu secured with a password; unauthorized users cannot access the gas detector. |
| Applications | Chemical industry; refineries; wastewater plants; boiler rooms; marine; storage of packed dangerous substances; food industry. |
| Source Conditions | The specifications described herein are subject to change without notice. |
| Accessories (separate Items) | Splash guard 5150227-00A: Sensor protection against splash water; Inline flow adapter 5150228-00A: Inline flow adapter for sample applications, connection 2×6mm, SS; Protective hood 5150226-00A: Protective hood SS, for optimal protection in “wet” protection areas, dimensions 315×300×138 mm; Isolation set EMC/RFI 5150231-00A: Isolation board, 160×160 mm; Protective bracket 5150225-00A: SS bracket, extra protection for use in warehouses; Conical collector hood 5150230-00A: Conical hood for ascending gases |
| Spare Gas Sensors (separate Items) | ST650 EX, Sensor 5150240-00A, 0-100 %LEL CH4: Gas sensor for standard applications; ST650 EX, Sensor 5150247-00A, 0-100 %LEL CH4: High temperature, applications up to 120 °C ambient temperature; ST650 EX, Sensor 5150241-00A, 0-100 %LEL: Gas sensor for combustible vapours containing halogens; ST650 EX, Sensor 5150242-00A, 0-100 %LEL Kerosene / 0-100 %LEL Gasoline / 0-10 %LEL NH3: Kerosene, Gasoline and Ammonia applications with listed ranges; ST650 EX, Sensor 5150243-00A, 0-100 Vol.% CH4: Thermal Conductivity sensor, measurements up to 0-100 Vol.% CH4; ST650 EX, Sensor 5150245-00A, 0-100 %LEL CH4: Infrared sensor (NDIR), Methane; ST650 EX, Sensor 5150246-00A, 0-100 %LEL C3H8: Infrared sensor (NDIR), Propane |
Compatibility
- CGD50/500
- CGS50/500
Manufacturer-listed system references
- Compatible systems
- CGD50/500; CGS50/500.
Check the original document for configuration, installation conditions and restrictions.
Accessories
- Sensor protection against splash water
- Inline flow adapter for sample applications, connection 2×6mm, SS
- Protective hood SS, for optimal protection in “wet” protection areas, dimensions 315×300×138 mm
- Isolation board, 160×160 mm
- SS bracket, extra protection for use in warehouses
- Conical hood for ascending gases
Original documents & sources
Source pages
Original manufacturer data retained. Product enquiry and technical sourcing by MAXONE Marine. Last reviewed: 2026-10-23T14:25:55.218069+00:00.