Connecting Global Safety Technology

CS-Loop M H Loop-Line Controller Module

Original manufacturer
Consilium / Salwico
Name
CS-Loop M H Loop-Line Controller Module
Model
CS-Loop M H
Part number
5210003-00A

Supply availability and delivery time require confirmation. A catalog reference does not imply stock.

Specifications

Manufacturer approvals / certificationsNot provided by manufacturer
Operating Voltage19–30 VDC
Operating Temperature-40 °C to +70 °C
Relative Humidity≤ 95 % RH non-condensing
MaterialNylon 6.6
Weight (with Housing)140 g ±5%
Ce ConformityEN 54-2
ApprovalsEN 50155, EN 45545-2
Certified According ToNot provided by manufacturer
Safety Integrity LevelSIL 1 and SIL 2
Safety Architecture TypeType B
Hft0
Sff97 %
Pfd1.96 × 10-4
Pfd Calculation BasisMTTR 8 h and proof test interval 1 year
Continuous Output200 mA
Maximum Output Current400 mA (< 15 minutes)
Redundant Power Supply InputsRedundant power supply inputs
Redundant Communication ChannelsRedundant communication channels
Fire Condition ChannelA channel for transmitting the fire condition
Invalid Dip-switch ConditionAll LEDs flashing means all DIP switches are OFF or all are ON; set them according to project documentation.
Shielded Loop-line ConditionConnect a shielded loop-line to the CS-IC10 shield terminal; do not connect it to the hazardous-area shield.
MountingHorizontal 35 mm DIN rail
Source DatasheetData sheet no. 5210003-00A_CS-Loop M H_M_EN_2022_F
Specification Change NoticeThe specifications described herein are subject to change without notice.
Overall Width29 mm
Body Width22.5 mm
Height99 mm
Depth114.5 mm
Connection ExamplesEx loop-line and Ex spur are distinct source examples; both show device addresses X/Y/Z and a CS-Isolator external earth connection. The examples do not imply unrestricted compatibility or physical wire routing.
Current Consumption70 mA at 24 V
Loop Line Output Nominal Voltage35 VDC
Maximum Loop Units150 loop units
Cable Terminals2.5 mm2
Storage Temperature-50 °C to +70 °C
Addressing MethodDIP switch
ColourYellow (RAL 1018)
Spare Part (module)CS-Loop M 5210002-00A
Spare Part (housing)5210069-00A
Loop Cable RequirementSee the Installation & Commissioning manual
Compatible Loop UnitsAll loop units that communicate with the IDAxt protocol
Production Mark2531/yyyy; yyyy = year of production
Indicator And Safety States (indicator-states) — Row 1 — IndicatorALARM
Indicator And Safety States (indicator-states) — Row 1 — Colour / PatternRed, steady
Indicator And Safety States (indicator-states) — Row 1 — Module StatusOne or more fire alarms are present
Indicator And Safety States (indicator-states) — Row 1 — Failure ClassificationFollow local procedures
Indicator And Safety States (indicator-states) — Row 2 — IndicatorALARM
Indicator And Safety States (indicator-states) — Row 2 — Colour / PatternRed, flashing
Indicator And Safety States (indicator-states) — Row 2 — Module StatusPre-alarm
Indicator And Safety States (indicator-states) — Row 2 — Failure ClassificationFollow local procedures
Indicator And Safety States (indicator-states) — Row 3 — IndicatorALARM
Indicator And Safety States (indicator-states) — Row 3 — Colour / PatternNone
Indicator And Safety States (indicator-states) — Row 3 — Module StatusThere are no alarms
Indicator And Safety States (indicator-states) — Row 3 — Failure ClassificationN/A
Indicator And Safety States (indicator-states) — Row 4 — IndicatorFAULT
Indicator And Safety States (indicator-states) — Row 4 — Colour / PatternYellow, steady
Indicator And Safety States (indicator-states) — Row 4 — Module StatusOne or more faults are present
Indicator And Safety States (indicator-states) — Row 4 — Failure Classification*
Indicator And Safety States (indicator-states) — Row 5 — IndicatorFAULT
Indicator And Safety States (indicator-states) — Row 5 — Colour / PatternYellow, flashing
Indicator And Safety States (indicator-states) — Row 5 — Module StatusModule is booting or re-scanning the loop
Indicator And Safety States (indicator-states) — Row 5 — Failure Classification*
Indicator And Safety States (indicator-states) — Row 6 — IndicatorFAULT
Indicator And Safety States (indicator-states) — Row 6 — Colour / PatternNone
Indicator And Safety States (indicator-states) — Row 6 — Module StatusThere are no faults
Indicator And Safety States (indicator-states) — Row 6 — Failure ClassificationN/A
Indicator And Safety States (indicator-states) — Row 7 — IndicatorPS (Power Supply)
Indicator And Safety States (indicator-states) — Row 7 — Colour / PatternGreen
Indicator And Safety States (indicator-states) — Row 7 — Module StatusOK
Indicator And Safety States (indicator-states) — Row 7 — Failure ClassificationN/A
Indicator And Safety States (indicator-states) — Row 8 — IndicatorPS (Power Supply)
Indicator And Safety States (indicator-states) — Row 8 — Colour / PatternYellow, steady
Indicator And Safety States (indicator-states) — Row 8 — Module StatusPower fault on one of the two power channels feeding the module. A single power fault does not prevent the loop module to communicate with the loop units.
Indicator And Safety States (indicator-states) — Row 8 — Failure ClassificationMinor fault*
Indicator And Safety States (indicator-states) — Row 9 — IndicatorPS (Power Supply)
Indicator And Safety States (indicator-states) — Row 9 — Colour / PatternYellow, flashing: 0.5 sec On, 0.5 sec Off.
Indicator And Safety States (indicator-states) — Row 9 — Module StatusBoot loader mode. Only active during firmware download to the loop module. In this mode the loop unit can't communicate with the loop units.
Indicator And Safety States (indicator-states) — Row 9 — Failure Classification*
Indicator And Safety States (indicator-states) — Row 10 — IndicatorPS (Power Supply)
Indicator And Safety States (indicator-states) — Row 10 — Colour / PatternYellow, flashing: 1 sec On, 0.5 sec Off.
Indicator And Safety States (indicator-states) — Row 10 — Module StatusSafe State Predefined state to avoid disturbing system integrity.
Indicator And Safety States (indicator-states) — Row 10 — Failure Classification*
Indicator And Safety States (indicator-states) — Row 11 — IndicatorCOM (Backbone communication)
Indicator And Safety States (indicator-states) — Row 11 — Colour / PatternGreen, steady
Indicator And Safety States (indicator-states) — Row 11 — Module StatusOK
Indicator And Safety States (indicator-states) — Row 11 — Failure ClassificationN/A
Indicator And Safety States (indicator-states) — Row 12 — IndicatorCOM (Backbone communication)
Indicator And Safety States (indicator-states) — Row 12 — Colour / PatternGreen, flashing
Indicator And Safety States (indicator-states) — Row 12 — Module StatusUnconfigured. Could be a configuration error in the application program file. (Communication working.)
Indicator And Safety States (indicator-states) — Row 12 — Failure ClassificationMinor fault*
Indicator And Safety States (indicator-states) — Row 13 — IndicatorCOM (Backbone communication)
Indicator And Safety States (indicator-states) — Row 13 — Colour / PatternYellow, steady
Indicator And Safety States (indicator-states) — Row 13 — Module StatusSystem fault
Indicator And Safety States (indicator-states) — Row 13 — Failure ClassificationMajor fault*
Indicator And Safety States (indicator-states) — Row 14 — IndicatorCOM (Backbone communication)
Indicator And Safety States (indicator-states) — Row 14 — Colour / PatternYellow, steady
Indicator And Safety States (indicator-states) — Row 14 — Module StatusNormal condition for defined slave module, if only channel 1 is used.
Indicator And Safety States (indicator-states) — Row 14 — Failure ClassificationN/A
Indicator And Safety States (indicator-states) — Row 15 — IndicatorCOM (Backbone communication)
Indicator And Safety States (indicator-states) — Row 15 — Colour / PatternYellow, flashing
Indicator And Safety States (indicator-states) — Row 15 — Module StatusCommunication fault on the backbone interface.
Indicator And Safety States (indicator-states) — Row 15 — Failure ClassificationMajor fault*
Indicator And Safety States (indicator-states) — Row 16 — IndicatorCOM (Backbone communication)
Indicator And Safety States (indicator-states) — Row 16 — Colour / PatternNone
Indicator And Safety States (indicator-states) — Row 16 — Module StatusNo communication
Indicator And Safety States (indicator-states) — Row 16 — Failure ClassificationMajor fault*
Indicator And Safety States (indicator-states) — Row 17 — IndicatorPS + COM (both flashing)
Indicator And Safety States (indicator-states) — Row 17 — Colour / PatternPS Yellow, flashing
Indicator And Safety States (indicator-states) — Row 17 — Module StatusTransferring software. (Download or upload.)
Indicator And Safety States (indicator-states) — Row 17 — Failure Classification*
Indicator And Safety States (indicator-states) — Row 18 — IndicatorPS + COM (both flashing)
Indicator And Safety States (indicator-states) — Row 18 — Colour / PatternCOM Green, flashing
Indicator And Safety States (indicator-states) — Row 18 — Module StatusTransferring software. (Download or upload.)
Indicator And Safety States (indicator-states) — Row 18 — Failure Classification*
System AssociationCFD5000

Compatibility

    Manufacturer-listed system references

    System association
    CFD5000

    Check the original document for configuration, installation conditions and restrictions.

    Original manufacturer documents and sources

    Accessories

    • Not provided by manufacturer

    Original documents & sources