Connecting Global Safety Technology

CS-IC22 SS WP Safety Input/Output Module

Original manufacturer
Consilium / Salwico
Name
CS-IC22 SS WP Safety Input/Output Module
Model
CS-IC22 SS WP
Part number
5210067-00A

Supply availability and delivery time require confirmation. A catalog reference does not imply stock.

Specifications

Manufacturer approvals / certificationsNot provided by manufacturer
Ingress ProtectionIP66
Cable GlandM20 for cable ø 6–13mm
Enclosure MaterialStainless steel AISI 304
Gasket MaterialPolyurethane and silicone
Weight1.685 kg ± 5%
Operating Voltage22–38 VDC
Sub-loop Current Limit5 mA
Relay Output Rating (30 Vdc)30 VDC, max 1 A
Relay Output Rating (110 Vdc)110 VDC, max 0.3 A, resistive load
Ce ConformityEN 54-17, EN 54-18
ApprovalsEN 50155, EN 45545-2
Current Certificate ValidityNot provided by manufacturer
Safety Architecture TypeType B
Hft0
Sff92 %
Pfdavg3.24 × 10-4
Pfdavg Calculation BasisMTTR 8 h and proof test interval 1 year
Safe I/o And Safe RelayTwo configurable Safe I/O and two Safe Relay contact outputs
Sub-loop Shield ConditionTerminate a shielded sub-loop cable at one end only; a shield terminated in the I/O unit requires a shielded loop line.
External Earth ConditionConnect the enclosure external earth connection to earth; see the Installation & Commissioning manual.
Source DatasheetData sheet no. 5210067-00A_CS-IC22 SS WP_Marine_EN_1.0
Specification Change NoticeThe specifications described herein are subject to change without notice.
Operating Current (normal Condition)0.1 mA ± 5%
Operating Current (alarm Condition, Led Activated)3 mA ± 5%
Switch-on Extended Operating Temperature (st1)+15 °C during 10 min
Body Width150 mm
Body Height150 mm
Body Depth80 mm
Overall Width200 mm
Overall Height196 mm
Mount Width175 mm
Mount Height106 mm
External Earth Connection ThreadM6
Product Illustration — G010977G010977 product illustration; source page 1; source SHA 8596d424e9eac44c90d9bcb68247e4755c256de9fe3de3501f328023dc541843; source bbox [112.429, 73.24, 309.067, 258.36]. The complete native illustration is retained in the source appendix; this is not a fragment-level numeric interpretation.
Location Of Dip Switches And Terminals — Figure 1 (g011267)Figure 1. Location of DIP switches and terminals on the PCB; source page 3; source SHA 8596d424e9eac44c90d9bcb68247e4755c256de9fe3de3501f328023dc541843; source bbox [303.638, 105.908, 510.236, 386.885]. The whole location context is preserved: ADDRESS and FUNCTION labels, S101, S102, J101, J102, J103, SHIELD, and the G011267 source figure. Address switch S101 is an 8-pole loop-address switch. Function switch S102 is a 4-pole factory-set switch, not used for current operation modes; do not change it.
Connection Example — Figure 2 (j101/j102/j103)Figure 2. Terminals J101, J102 and J103; source page 5; source SHA 8596d424e9eac44c90d9bcb68247e4755c256de9fe3de3501f328023dc541843; source bbox [95.039, 105.973, 499.598, 361.699]. Loop IN 1+ / 2- Loop/SCI; Loop OUT 3+ / 4- Loop/SCI; Sub-loop 1 5+ / 6- with 1.5 kΩ and 3.3 kΩ examples; Sub-loop 2 7+ / 8- with 1.5 kΩ and 3.3 kΩ examples; Relay 1 11 C / 12 NC / 14 NO; Relay 2 21 C / 22 NC / 24 NO. External connection shown in normal not active state. Shielded sub-loop cable is terminated at one end only; if the shield is terminated in the I/O unit, the loop line must be shielded.
Connection Example — Figure 3 (lhd)Figure 3. Linear Heat Detection (LHD) cable; source page 5; source SHA 8596d424e9eac44c90d9bcb68247e4755c256de9fe3de3501f328023dc541843; source bbox [95.039, 373.707, 499.598, 627.960]. Loop IN 1+ / 2- Loop/SCI; Loop OUT 3+ / 4- Loop/SCI; Sub-loop 1 5+ / 6- with 1.5 kΩ and 3.3 kΩ examples; Sub-loop 2 7+ / 8- with LHD and 1.5 kΩ + 1.5 kΩ examples; Relay 1 11 C / 12 NC / 14 NO; Relay 2 21 C / 22 NC / 24 NO. External connection shown in normal not active state. Shielded sub-loop cable is terminated at one end only; if the shield is terminated in the I/O unit, the loop line must be shielded.
Installation CautionDo not use electrical screwdriver. Maximum torque 2 Nm.
Address Switch Configuration (s101)8-pole S101 loop-address DIP switch; 1–150 valid addresses; binary values 1/2/4/8/16/32/64/128; use a pointed tool of suitable size.
Sub-loop Remote Current Limit5 mA
Loop CommunicationIDAxt protocol
Temperature ClassesEN 50155:2017
Loop Cable RequirementSee the Installation & Commissioning manual
Production Mark2531/yyyy; yyyy = year of production
Technical Data (technical-data) — Row 1 — Source Column 1Operating voltage 22–38 VDC
Technical Data (technical-data) — Row 2 — Source Column 1Operating current:
Technical Data (technical-data) — Row 3 — Source Column 1- Normal condition 0.1 mA ± 5%
Technical Data (technical-data) — Row 4 — Source Column 1- Alarm condition with 3 mA ± 5% LED activated
Technical Data (technical-data) — Row 5 — Source Column 1Sub-Loop (Remote Current limited: 5 mA indication, supervised dry-contact reading)
Technical Data (technical-data) — Row 6 — Source Column 1Loop communication IDAxt protocol
Technical Data (technical-data) — Row 7 — Source Column 1Relay output 30 VDC, max 1 A 110 VDC, max 0.3 A resestive load
Technical Data (technical-data) — Row 8 — Source Column 1Operating -40 °C to +70 °C temperature
Technical Data (technical-data) — Row 9 — Source Column 1Switch-on extended +15 °C during 10 min operating temperature (ST1)
Technical Data (technical-data) — Row 10 — Source Column 1Temperature classes EN 50155:2017 according to
Technical Data (technical-data) — Row 11 — Source Column 1Storage temperature -50 °C to +70 °C
Technical Data (technical-data) — Row 12 — Source Column 1Relative humidity ≤ 95 % RH non-condensing
Technical Data (technical-data) — Row 13 — Source Column 1Addressing method DIP switch
Technical Data (technical-data) — Row 14 — Source Column 1Ingress protection IP66
Technical Data (technical-data) — Row 15 — Source Column 1Cable gland M20 for cable ø 6–13mm Material: Nickel plated brass
Technical Data (technical-data) — Row 16 — Source Column 1Cable terminals 2.5 mm2
Technical Data (technical-data) — Row 17 — Source Column 1Material Enclosure: Stainless steel AISI 304 Gasket: Polyurethane and Silicone
Technical Data (technical-data) — Row 18 — Source Column 1Weight 1.685 kg ± 5%
Technical Data (technical-data) — Row 19 — Source Column 1Colour Polished surface
Technical Data (technical-data) — Row 20 — Source Column 1Loop cable See the Installation & requirement Commissioning manual
Technical Data (technical-data) — Row 21 — Source Column 1CE Conformity EN 54-17, EN 54-18 Approvals EN 50155, EN 45545-2
Technical Data (technical-data) — Row 22 — Source Column 1Certified according to 2531/yyyy yyyy = year of production
Functional Safety Data (functional-safety-data) — Row 1 — Source Column 1Type B
Functional Safety Data (functional-safety-data) — Row 2 — Source Column 1HFT 0
Functional Safety Data (functional-safety-data) — Row 3 — Source Column 1SFF 92 %
Functional Safety Data (functional-safety-data) — Row 4 — Source Column 1PFDavg 3.24 × 10-4
Functional Safety Data (functional-safety-data) — Row 5 — Source Column 1PFDavg is calculated for MTTR 8 h and proof test interval 1 year. Suitable for use in SIL 1 and SIL 2 environments.
Built-in Short-circuit Data (short-circuit-data) — Row 1 — Source Column 1Ic max (Maximum Continuous 500 mA current)
Built-in Short-circuit Data (short-circuit-data) — Row 2 — Source Column 1current) Is max (Maximum Switching 800 mA current)
Built-in Short-circuit Data (short-circuit-data) — Row 3 — Source Column 1Current when short circuited < 1 mA (IL max)
Built-in Short-circuit Data (short-circuit-data) — Row 4 — Source Column 1Open to Close voltage 22 ± 2 VDC
Built-in Short-circuit Data (short-circuit-data) — Row 5 — Source Column 1Open to Close, maximum load ≈1.2 kΩ expressed in ohms on the non- energized side
Built-in Short-circuit Data (short-circuit-data) — Row 6 — Source Column 1Close to Open voltage 14 ± 2 VDC
Terminal Connections (terminal-connections) — Row 1 — Source Column 11 + Loop
Terminal Connections (terminal-connections) — Row 1 — Source Column 21 + Loop
Terminal Connections (terminal-connections) — Row 2 — Source Column 12 - Loop/SCI
Terminal Connections (terminal-connections) — Row 2 — Source Column 22 - Loop/SCI
Terminal Connections (terminal-connections) — Row 3 — Source Column 13 + Loop
Terminal Connections (terminal-connections) — Row 3 — Source Column 23 + Loop
Terminal Connections (terminal-connections) — Row 4 — Source Column 14 - Loop/SCI
Terminal Connections (terminal-connections) — Row 4 — Source Column 24 - Loop/SCI
Terminal Connections (terminal-connections) — Row 5 — Source Column 15 + Sub-loop 1, High
Terminal Connections (terminal-connections) — Row 5 — Source Column 25 + Sub-loop 1, High
Terminal Connections (terminal-connections) — Row 6 — Source Column 16 - Sub-loop 1, Low
Terminal Connections (terminal-connections) — Row 6 — Source Column 26 - Sub-loop 1, Low
Terminal Connections (terminal-connections) — Row 7 — Source Column 17 + Sub-loop 2, High
Terminal Connections (terminal-connections) — Row 7 — Source Column 27 + Sub-loop 2, High
Terminal Connections (terminal-connections) — Row 8 — Source Column 18 - Sub-loop 2, Low
Terminal Connections (terminal-connections) — Row 8 — Source Column 28 - Sub-loop 2, Low
Terminal Connections (terminal-connections) — Row 9 — Source Column 111 C
Terminal Connections (terminal-connections) — Row 10 — Source Column 112 NC
Terminal Connections (terminal-connections) — Row 10 — Source Column 2Relay output 1
Terminal Connections (terminal-connections) — Row 11 — Source Column 114 NO
Terminal Connections (terminal-connections) — Row 11 — Source Column 2Relay output 1
Terminal Connections (terminal-connections) — Row 12 — Source Column 121 C
Terminal Connections (terminal-connections) — Row 13 — Source Column 122 NC
Terminal Connections (terminal-connections) — Row 13 — Source Column 2Relay output 2
Terminal Connections (terminal-connections) — Row 14 — Source Column 124 NO
Terminal Connections (terminal-connections) — Row 14 — Source Column 2Relay output 2
Safe I/o Configurations (safe-io-configurations) — Row 1 — I/o TypeInput
Safe I/o Configurations (safe-io-configurations) — Row 1 — ConditionGeneral
Safe I/o Configurations (safe-io-configurations) — Row 1 — Active LevelH/L
Safe I/o Configurations (safe-io-configurations) — Row 1 — MonitoredX
Safe I/o Configurations (safe-io-configurations) — Row 1 — Additional ConditionX
Safe I/o Configurations (safe-io-configurations) — Row 2 — ConditionAlive signal NA X
Safe I/o Configurations (safe-io-configurations) — Row 2 — Active LevelAlive signal NA X
Safe I/o Configurations (safe-io-configurations) — Row 2 — MonitoredAlive signal NA X
Safe I/o Configurations (safe-io-configurations) — Row 2 — Additional ConditionAlive signal NA X
Safe I/o Configurations (safe-io-configurations) — Row 3 — I/o TypeOutput
Safe I/o Configurations (safe-io-configurations) — Row 3 — ConditionRemote Indication (RIL)
Safe I/o Configurations (safe-io-configurations) — Row 3 — Active LevelNA
Safe Relay Configurations (safe-relay-configurations) — Row 1 — OutputOutput
Safe Relay Configurations (safe-relay-configurations) — Row 1 — ConditionDisable-ment
Safe Relay Configurations (safe-relay-configurations) — Row 1 — Active LevelH
Safe Relay Configurations (safe-relay-configurations) — Row 2 — OutputOutput
Safe Relay Configurations (safe-relay-configurations) — Row 2 — ConditionGeneral
Safe Relay Configurations (safe-relay-configurations) — Row 2 — Active LevelH/L
Safe Relay Configurations (safe-relay-configurations) — Row 2 — Additional ConditionX
System AssociationCFD5000

Compatibility

    Manufacturer-listed system references

    System association
    CFD5000

    Check the original document for configuration, installation conditions and restrictions.

    Original manufacturer documents and sources

    Accessories

    • Not provided by manufacturer

    Original documents & sources

    Source pages