CD-CGI ADDR Enclosed Intrinsically Safe Loop Isolator
- Original manufacturer
- Consilium / Salwico
- Name
- CD-CGI ADDR Enclosed Intrinsically Safe Loop Isolator
- Model
- CD-CGI ADDR
- Part number
- 5600965-00
Supply availability and delivery time require confirmation. A catalog reference does not imply stock.
Specifications
| Manufacturer approvals / certifications | Not provided by manufacturer |
|---|---|
| Load-limit Applicability | Full limits apply if the external circuit has no combined lumped Li and Ci above 1% of the listed limits; OR L/C is distributed as cable; OR only lumped L or only lumped C is combined with cable. |
| Is / Non-is Conductor Separation | Minimum 50 mm separation; conductors between cable entrance and terminals must be as short as possible and must not cross sides. Place cable glands as in the original dimension drawing. |
| M-edition Compatible Systems | CS3000; CS4000; NSAC-1; Salwico Cargo; Salwico Cruise; Salwico LNG; Salwico Offshore; Salwico Ro/Pax; Salwico Workboat; Salwico Yacht; Salwico Navy; OEM Extinguish |
| Loop-screen Termination | If loop IN/OUT cable has a screen, terminate it on the supplied loop-screen connector. Do NOT connect this loop screen to the enclosure earth bolt. |
| Terminal And Mounting Drawings | Terminals:IN11(+)/12(-),OUT13(+)/14(-),IS41(+)/42(-). Original bottom view:4ר5 mm mounting holes;95 mm horizontal dimension and165 mm spacing, as drawn. |
| Loop Supply / Working Voltage | Loop-powered from fire alarm panel, no separate supply. 27–38 V DC; nominal 36 V DC. Voltages are DC unless specified otherwise. |
| Other Combined-lumped Circuits | In other situations with combined lumped inductance/capacitance, up to 50% of each listed L and C value is allowed. |
| Internal Cable Routing | Original compartments:1 fire-system cables only;2 no cables;3 IS-unit cable only. The assembly itself is installed in the safe area. |
| Is Communication Capacitance | To avoid communication-signal loss, capacitance on the intrinsically safe side must not exceed 300 nF. |
| Manufacturer Article Number | 5600965-00 |
| Max Is Output Current Io | 92.8 mA |
| Group Iic Connected-load Limits | Capacitance 77 nF; inductance 4.3 mH OR L/R ratio 55 µH/Ω. |
| Enclosure Ambient Humidity | 0–100% RH |
| Overall Dimensions | 110 mm wide ×235 mm high ×95 mm deep, including cable gland. |
| Cable Terminals | Maximum 2.5 mm² conductor |
| Ingress Protection | IP55 |
| Loop Capacity | Maximum 5 isolators per addressable detector loop; up to 20 IS line units per isolator. Actual quantity depends on hazardous-area cable length and must be verified by Ex-calculation. |
| Is-cable Screen / Earth | Connect the hazardous-area cable screen to its dedicated enclosure earth bolt. Keep the screen open circuit at the last IS unit; maximum screen length inside enclosure10 cm. |
| Enclosure Materials | Base:polycarbonate; cover:glass-fibre-reinforced polycarbonate; seal:polyurethane; cover screws:glass-fibre-reinforced polyamide; colour:grey. |
| Separate Earthing Routes | Original drawing D:closest Intrinsically Safe Earth point; E:screen to dedicated enclosure earth bolt; F:closest earth point. Preserve the original separate routes. |
| Installation Location | Non-hazardous (safe) area; interface to Salwico IS addressable detectors/manual call points and IS line units. |
| Group Iib Connected-load Limits | Capacitance 640 nF; inductance 17 mH OR L/R ratio 199 µH/Ω. The separate 300 nF communication condition still applies. |
| Cable Armour | Bond armour of all armoured cables to the appropriate internal earth points on both sides for EMC and intrinsic safety. |
| Printed Isolator Marking | II 1G [Ex ia Ga] IIC;0051 as printed. Preserve source marking; no current certificate validity or installed Zone inferred. |
| Internal Isolator Spare | 5600963-00 C-GI ADDR Ex H; separate complete SKU, not an alias for CD-CGI ADDR. |
| Max Is Output Voltage Uo | 28 V |
| Max Is Output Power Po | 649.8 mW |
| Enclosure Operating Temperature | -40 °C to +60 °C, per this Marine_EN_2.0 complete-unit datasheet. |
| Weight | 850 g ±5%, including internal components |
| Internal Ci / Li | Maximum Ci 5.14 nF; Li negligible. |
| Storage Temperature | -40 °C to +70 °C |
| Cable Glands | M20; cable diameter6–13 mm. |
Compatibility
- M-edition scope: CS3000, CS4000, NSAC-1, Salwico Cargo, Salwico Cruise, Salwico LNG, Salwico Offshore, Salwico Ro/Pax, Salwico Workboat, Salwico Yacht, Salwico Navy, OEM Extinguish. I0 systems remain separate.
Accessories
- Internal spare isolator5600963-00 C-GI ADDR Ex H.
- Loop cable-screen connector is included in delivery; follow the separate screen,armour and IS-earth drawings.
Original documents & sources
- Original M-edition manufacturer datasheet (PDF)
- Separate I0-edition manufacturer reference; application scope not merged
Source pages
- https://www.consiliumsafety.com/content/uploads/products/en/5600965-00/5600965-00_CD-CGI%20ADDR_M_EN.pdf
- https://www.consiliumsafety.com/content/uploads/products/en/5600965-00/5600965-00_CD-CGI%20ADDR_M_EN.pdf
- https://www.consiliumsafety.com/content/uploads/products/en/5600965-00/5600965-00_CD-CGI%20ADDR_M_EN.pdf
Original manufacturer data retained. Product enquiry and technical sourcing by MAXONE Marine. Last reviewed: 2026-10-23T08:18:57.623989+00:00.